Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Braz. j. med. biol. res ; 49(10): e5310, 2016. graf
Article in English | LILACS | ID: biblio-951650

ABSTRACT

Although it is well known that physical training ameliorates brain oxidative function after injuries by enhancing the levels of neurotrophic factors and oxidative status, there is little evidence addressing the influence of exercise training itself on brain oxidative damage and data is conflicting. This study investigated the effect of well-established swimming training protocol on lipid peroxidation and components of antioxidant system in the rat brain. Male Wistar rats were randomized into trained (5 days/week, 8 weeks, 30 min; n=8) and non-trained (n=7) groups. Forty-eight hours after the last session of exercise, animals were euthanized and the brain was collected for oxidative stress analysis. Swimming training decreased thiobarbituric acid reactive substances (TBARS) levels (P<0.05) and increased the activity of the antioxidant enzyme superoxide dismutase (SOD) (P<0.05) with no effect on brain non-enzymatic total antioxidant capacity, estimated by FRAP (ferric-reducing antioxidant power) assay (P>0.05). Moreover, the swimming training promoted metabolic adaptations, such as increased maximal workload capacity (P<0.05) and maintenance of body weight. In this context, the reduced TBARS content and increased SOD antioxidant activity induced by 8 weeks of swimming training are key factors in promoting brain resistance. In conclusion, swimming training attenuated oxidative damage and increased enzymatic antioxidant but not non-enzymatic status in the rat brain.


Subject(s)
Animals , Male , Physical Conditioning, Animal/physiology , Swimming/physiology , Brain/metabolism , Oxidative Stress/physiology , Exercise Therapy/methods , Antioxidants/metabolism , Reference Values , Spectrophotometry , Superoxide Dismutase/analysis , Time Factors , Body Weight , Lipid Peroxidation/physiology , Random Allocation , Reproducibility of Results , Reactive Oxygen Species/metabolism , Malondialdehyde/analysis , Malondialdehyde/metabolism , Antioxidants/analysis
2.
Braz. j. med. biol. res ; 47(4): 307-3015, 8/4/2014. graf
Article in English | LILACS | ID: lil-705765

ABSTRACT

Dye exclusion tests are used to determine the number of live and dead cells. These assays are based on the principle that intact plasma membranes in live cells exclude specific dyes, whereas dead cells do not. Although widely used, the trypan blue (TB) exclusion assay has limitations. The dye can be incorporated by live cells after a short exposure time, and personal reliability, related to the expertise of the analyst, can affect the results. We propose an alternative assay for evaluating cell viability that combines the TB exclusion test and the high sensitivity of the flow cytometry technique. Previous studies have demonstrated the ability of TB to emit fluorescence when complexed with proteins. According to our results, TB/bovine serum albumin and TB/cytoplasmic protein complexes emit fluorescence at 660 nm, which is detectable by flow cytometry using a 650-nm low-pass band filter. TB at 0.002% (w/v) was defined as the optimum concentration for distinguishing unstained living cells from fluorescent dead cells, and fluorescence emission was stable for 30 min after cell treatment. Although previous studies have shown that TB promotes green fluorescence quenching, TB at 0.002% did not interfere with green fluorescence in human live T-cells stained with anti-CD3/fluorescein isothiocyanate (FITC) monoclonal antibody. We observed a high correlation between the percentage of propidium iodide+CD3/FITC+ and TB+CD3/FITC+ cells, as well as similar double-stained cell profiles in flow cytometry dot-plot graphs. Taken together, the results indicate that a TB exclusion assay by flow cytometry can be employed as an alternative tool for quick and reliable cell viability analysis.


Subject(s)
Humans , Young Adult , /blood , Flow Cytometry/standards , Leukocytes, Mononuclear/metabolism , Trypan Blue , Cell Count , Cell Separation , Cell Survival , Cell Membrane/physiology , Fluorescence , Immunophenotyping , Indicators and Reagents/standards , Multiprotein Complexes/standards , Professional Competence , Propidium/standards , Staining and Labeling , Serum Albumin, Bovine/standards
3.
Braz. j. med. biol. res ; 44(10): 1054-1059, Oct. 2011. ilus
Article in English | LILACS | ID: lil-600698

ABSTRACT

Epilepsy is a neurological disorder associated with excitatory and inhibitory imbalance within the underlying neural network. This study evaluated inhibitory γ-amino-butyric acid (GABA)ergic modulation in the CA1 region of the hippocampus of male Wistar rats and Wistar audiogenic rats (aged 90 ± 3 days), a strain of inbred animals susceptible to audiogenic seizures. Field excitatory postsynaptic potentials and population spike complexes in response to Schaffer collateral fiber stimulation were recorded in hippocampal slices before and during application of picrotoxin (50 µM, 60 min), a GABA A antagonist, and the size of the population spike was quantified by measuring its amplitude and slope. In control audiogenic-resistant Wistar rats (N = 9), picrotoxin significantly increased both the amplitude of the population spike by 51 ± 19 percent and its maximum slope by 73 ± 21 percent. In contrast, in slices from Wistar audiogenic rats (N = 6), picrotoxin caused no statistically significant change in population spike amplitude (33 ± 46 percent) or slope (11 ± 29 percent). Data are reported as means ± SEM. This result indicates a functional reduction of GABAergic neurotransmission in hippocampal slices from Wistar audiogenic rats.


Subject(s)
Animals , Male , Rats , CA1 Region, Hippocampal/drug effects , Epilepsy/metabolism , GABA Antagonists/pharmacology , Picrotoxin/pharmacology , Synaptic Transmission/drug effects , gamma-Aminobutyric Acid/metabolism , CA1 Region, Hippocampal/metabolism , Neural Inhibition/drug effects , Neural Inhibition/physiology , Rats, Wistar , Synapses/drug effects , Synapses/physiology
4.
Braz. j. med. biol. res ; 39(9): 1249-1253, Sept. 2006. ilus
Article in English | LILACS | ID: lil-435429

ABSTRACT

Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.


Subject(s)
Animals , Rabbits , Intraocular Pressure/physiology , Signal Processing, Computer-Assisted , Transducers, Pressure , Kinetics , Reproducibility of Results , Sensitivity and Specificity , Time Factors , Trabeculectomy/methods , Videotape Recording
SELECTION OF CITATIONS
SEARCH DETAIL